| Wood-Plastic Composite (WPC) | Wood fibers or flour combined with thermoplastic resin, pigments, and performance additives. | Rainscreen boards, slatted cladding, siding planks, and façade battens; commonly 15–25 mm thick. | Approximately 10–16 kg/m², depending on profile and density. | US$12–30/ft² | Mechanical clips or screws on timber or metal battens over a drained and ventilated cavity. Allow movement at joints. | Wash with mild detergent and water once or twice per year. Inspect fasteners, joints, drainage gaps, and surface fading. | Approximately 20–30 years when correctly detailed and maintained. | Good resistance to rot, insects, and moisture. Color may weather, and thermal expansion can cause movement if gaps are inadequate. Combustibility varies by formulation. | Residential façades, balconies, accent walls, and projects requiring a wood-like appearance with low repainting needs. |
| Fiber-Cement Composite Panels | Portland cement, cellulose fibers, mineral fillers, water, and curing additives. | Flat façade sheets, lap siding, shingles, and plank systems; commonly 8–12 mm thick. | Approximately 12–18 kg/m², depending on thickness and profile. | US$10–25/ft² | Installed over sheathing or a ventilated rainscreen using corrosion-resistant screws, rivets, or concealed clips. Cut edges may require sealing. | Periodic cleaning with low-pressure water and mild detergent. Repaint or reseal only when the specified coating reaches the end of its maintenance cycle. | Approximately 30–50 years with proper detailing and coating maintenance. | Very good dimensional stability, impact resistance, and fire performance. Panels can crack from improper handling or insufficient movement joints. | Low-rise and mid-rise façades, fire-conscious designs, painted exterior elevations, and durable rainscreen assemblies. |
| Exterior High-Pressure Laminate (HPL) | Kraft-paper or cellulose layers impregnated with thermosetting resin and fused under heat and pressure. | Decorative façade sheets, cassette panels, and rainscreen planks; commonly 6–12 mm thick. | Approximately 8–14 kg/m². | US$18–40/ft² | Fixed with exposed fasteners, concealed clips, or cassette rails on a drained and ventilated subframe. Accurate joint layout is essential. | Clean with water and non-abrasive detergent. Check joints, edge details, and exposed hardware during annual façade inspections. | Approximately 30–50 years, subject to ultraviolet exposure, edge protection, and installation quality. | Excellent color and scratch resistance for many applications. Requires correct ventilation and movement allowances to control moisture and thermal stresses. | Contemporary commercial buildings, schools, residential façades, and projects needing a broad range of colors and textures. |
| Aluminum Composite Material (ACM) | Two aluminum skins bonded to a polymer or mineral-filled core; core type strongly affects fire performance. | Flat sheets, routed-and-returned cassettes, column covers, and custom folded panels; commonly 3–6 mm thick. | Approximately 5–8 kg/m². | US$15–35/ft² | Installed as cassettes or face-fastened sheets on aluminum or galvanized-steel rails. Use a code-compliant core and cavity/fire-stopping design. | Usually limited to periodic washing and inspection of sealants, joints, fasteners, and coating condition. | Approximately 30–50 years; coastal and industrial environments may require more frequent inspections. | Lightweight, corrosion-resistant, and highly formable. Performance depends on coating quality, galvanic isolation, wind design, and the selected core. | Commercial façades, parapets, soffits, entrance features, and lightweight renovation projects. |
| Insulated Metal Composite Panels | Factory-formed metal skins bonded to a rigid insulation core, commonly mineral wool, polyisocyanurate, or polyurethane. | Interlocking wall panels, typically 50–200 mm thick, with long panels designed for rapid enclosure. | Approximately 10–25 kg/m², depending on thickness, skins, and insulation core. | US$14–32/ft² | Fastened to structural framing with concealed or exposed fixings. Panel joints, flashings, vapor control, and fire stopping must be installed continuously. | Clean exterior surfaces as needed and inspect joint sealants, closures, flashings, coatings, and penetrations at least annually. | Approximately 30–40 years for the complete wall system; metal coatings and sealants may need earlier renewal. | Provides continuous insulation, rapid installation, and good air and water control when joints are correctly assembled. Thermal bridging and moisture risk increase with poor detailing. | Warehouses, factories, cold-storage buildings, modular construction, and energy-conscious commercial enclosures. |
| Glass-Fiber-Reinforced Concrete (GFRC) | Cementitious matrix reinforced with alkali-resistant glass fibers, often produced as thin architectural panels. | Large-format rainscreen panels, molded façade elements, cornices, and custom architectural shapes; often 12–25 mm thick. | Approximately 30–55 kg/m², depending on geometry and reinforcement. | US$25–60/ft² | Suspended from engineered brackets or rails with adjustable anchors. Requires lifting equipment, movement joints, and careful panel alignment. | Low-pressure washing and periodic inspection for staining, sealant aging, anchor condition, and localized cracking. | Approximately 50 years or more when engineered, installed, and maintained correctly. | High resistance to fire, weather, and impact when properly designed. Heavy loads, connection design, water management, and freeze-thaw exposure require professional engineering. | Civic buildings, premium façades, feature walls, curved forms, and projects requiring a concrete appearance with reduced panel thickness. |