| Water-Based Acrylic Intumescent | Interior structural steel, commercial buildings, public facilities, and protected indoor areas. | Approximately 0.5–3.0 mm, depending on the required protection period, steel section factor, and tested system. | Commonly specified for approximately 30–120 minutes when used within a tested steel protection system. | EN 13381-8; EN 13501-2; ASTM E119 or UL 263 where applicable; ASTM E84 for surface-burning characteristics when required. | Generally suited to dry interior service. Long-term exposure to condensation, high humidity, or freezing may require a compatible primer and topcoat. | Usually lower odor and lower VOC than solvent-based alternatives, but the safety data sheet must confirm VOC content, preservatives, flash point, and ventilation requirements. | Independent fire-test report, classification report, approved primer/topcoat compatibility, application specification, and VOC documentation for the destination market. | Check wet-film and dry-film control, recoat windows, humidity limits, substrate preparation, curing time, and whether the tested system matches the actual steel profile. |
| Solvent-Based Epoxy Intumescent | Industrial steel, offshore or semi-exposed structures, petrochemical facilities, and areas requiring stronger mechanical resistance. | Approximately 1.0–6.0 mm; thicker systems may require multiple coats and controlled application procedures. | Commonly specified for approximately 60–180 minutes, subject to the tested assembly, loading conditions, and section factor. | EN 13381-8; EN 13501-2; ASTM E119 or UL 263; hydrocarbon fire testing may be required for certain industrial applications. | Typically offers better resistance to impact, abrasion, and intermittent moisture than many water-based systems. Continuous service temperature must be confirmed for the formulation. | May contain flammable solvents and higher VOC levels. Require explosion-control measures, suitable respiratory protection, grounding, and ventilation during application. | Fire-test evidence for the exact coating build-up, SDS, VOC or emissions declaration, transport classification, and regional chemical compliance documents. | Evaluate pot life, mixing ratio, application equipment, maximum recoat interval, holiday detection, abrasion resistance, and repair procedures after mechanical damage. |
| Cementitious or Vermiculite Spray Coating | Structural steel, concrete, tunnels, car parks, industrial buildings, and large-area passive fire protection. | Approximately 6–50 mm or more, depending on the substrate, fire duration, density, and design temperature. | Commonly specified for approximately 60–240 minutes in approved assemblies; some systems are designed for higher fire durations. | EN 13381 series; EN 13501-2; ASTM E119 or UL 263; ASTM E736 or equivalent adhesion testing where specified. | Suitable for many interior and semi-exposed applications when protected from excessive water, impact, and freeze-thaw conditions. A sealer or topcoat may be needed. | Generally low in solvent emissions, but dust can be generated during handling and spraying. Cementitious products may be alkaline and require eye, skin, and respiratory protection. | Fire classification, density and adhesion data, environmental durability documentation, substrate-primer compatibility, and installation method statement. | Check surface profile, mesh or reinforcement requirements, thickness tolerance, overspray control, curing conditions, repairability, weight addition, and final appearance. |
| Silicone or Elastomeric Fire-Resistive Coating | Exterior or high-moisture environments, industrial structures, façades, cable systems, and applications requiring flexibility. | Typically approximately 1.0–10.0 mm, depending on the tested application and fire exposure. | Often specified for approximately 30–120 minutes; performance varies substantially between structural, cable, façade, and penetration systems. | Application-specific standards may include EN 1363, EN 1366, EN 13501, ASTM E814, UL 1479, or other locally recognized methods. | Designed for improved weathering, movement, or moisture tolerance. Confirm ultraviolet resistance, minimum application temperature, and continuous service temperature. | VOC and cure chemistry vary widely. Some systems release moisture or other by-products during curing; review the SDS and confined-space requirements. | Use-specific fire-test report, movement and weathering data, adhesion results, compatibility statement, and certification accepted in the importing country. | Do not compare results across unrelated applications. Confirm the substrate, joint or penetration geometry, fire direction, movement requirement, and installation accessories. |
| Fire-Retardant Coating for Wood and Cellulosic Materials | Timber, plywood, wall panels, interior joinery, decorative surfaces, and selected building components. | Typically specified by wet application rate or dry film thickness; approximately 0.2–1.0 mm is common, but the approved value is product-specific. | Usually evaluated for reduced flame spread and smoke development rather than structural fire resistance. Duration claims must be tied to a specific tested assembly. | EN 13501-1; ASTM E84; ASTM E2768; ISO 5660; national surface-spread or smoke-development methods as required. | Interior use is common. Exterior use requires verified resistance to rain, ultraviolet exposure, abrasion, and repeated humidity changes. | Water-based products may have lower odor, while biocides, preservatives, and solvents can still present hazards. Confirm emissions, toxicity, and re-entry requirements. | Reaction-to-fire classification, emissions or indoor-air documentation, substrate-specific test report, maintenance instructions, and treatment-retention records. | Verify the exact wood species, moisture content, density, surface finish, application rate, sanding or refinishing limits, and whether the coating remains effective after cutting. |
| Firestop Coating for Cables and Penetrations | Cable trays, electrical penetrations, pipes, ducts, joints, and service openings in fire-rated walls or floors. | Often approximately 1–3 mm for cable coatings; penetration and joint systems may require substantially thicker, layered, or combined materials. | Commonly designed for 60–240 minutes, but the rating depends on the complete penetration or joint system rather than the coating alone. | EN 1366-3; EN 1366-4; EN 13501-2; ASTM E814; UL 1479; ASTM E1966 or UL 2079 for joint systems where applicable. | Service conditions depend on cable type, movement, moisture, chemicals, and access for inspection. Confirm compatibility with insulation and sheathing materials. | Review VOC, curing chemistry, skin and eye hazards, electrical isolation requirements, and fire performance after aging or environmental exposure. | System listing or classification, tested penetration configuration, installation drawings, cable or pipe compatibility data, and inspection and maintenance procedure. | Match the tested cable fill, opening size, wall or floor construction, backing material, annular space, and required movement or seismic classification. |