| 1 | Single run capacitor | 5 µF | 370/440 VAC | Small PSC blower or condenser fan motor | Typically ±5% | Approximately −40°C to +70°C | 2 terminals | Suitable for low-capacitance fan motors when the nameplate specifies 5 µF. |
| 2 | Single run capacitor | 7.5 µF | 370/440 VAC | Small to medium PSC fan motor | Typically ±5% | Approximately −40°C to +70°C | 2 terminals | A common value for fractional-horsepower blower and outdoor fan applications. |
| 3 | Single run capacitor | 10 µF | 370/440 VAC | Medium PSC blower or condenser fan motor | Typically ±5% | Approximately −40°C to +70°C | 2 terminals | The higher 440 VAC rating provides useful voltage margin in many replacement applications. |
| 4 | Single run capacitor | 15 µF | 370/440 VAC | Medium air-handler or condenser fan motor | Typically ±5% | Approximately −40°C to +70°C | 2 terminals | A practical mid-range specification for motors requiring moderate auxiliary-winding support. |
| 5 | Single run capacitor | 20 µF | 440 VAC | Larger PSC blower or condenser fan motor | Typically ±5% | Approximately −40°C to +70°C | 2 terminals | A 440 VAC design is appropriate where the motor specification calls for 20 µF. |
| 6 | Single run capacitor | 25 µF | 440 VAC | Medium compressor or high-output fan motor | Typically ±5% | Approximately −40°C to +70°C | 2 terminals | Offers a durable single-value format for compressor or fan circuits that require 25 µF. |
| 7 | Dual run capacitor | 30/5 µF | 440 VAC | Single-phase split-system compressor and condenser fan | Typically ±5% | Approximately −40°C to +70°C | 3 terminals: C, HERM, FAN | Combines compressor and fan capacitance in one enclosure when both nameplate values are 30/5 µF. |
| 8 | Dual run capacitor | 35/5 µF | 440 VAC | Medium split-system compressor and condenser fan | Typically ±5% | Approximately −40°C to +70°C | 3 terminals: C, HERM, FAN | A compact replacement profile for systems requiring 35 µF compressor and 5 µF fan sections. |
| 9 | Dual run capacitor | 40/5 µF | 440 VAC | Larger residential or light-commercial split-system unit | Typically ±5% | Approximately −40°C to +70°C | 3 terminals: C, HERM, FAN | Useful where the compressor circuit requires 40 µF and the condenser fan requires 5 µF. |
| 10 | Dual run capacitor | 45/5 µF | 440 VAC | Higher-capacity residential or light-commercial compressor system | Typically ±5% | Approximately −40°C to +70°C | 3 terminals: C, HERM, FAN | Provides a common dual-capacitor configuration for larger compressor circuits with a 5 µF fan section. |