| Manufacturer Profile 01 | Online gas density transmitter | Thermal conductivity with temperature compensation | Hydrogen, helium, nitrogen, methane, mixed gases | 0.05–2.00 kg/m³ | Typically ±1.0% of span | 4–20 mA, HART, RS-485/Modbus | Threaded or flanged gas sampling cell | Available on selected configurations | ISO 9001 commonly listed; hazardous-area certificate must be verified by model |
| Manufacturer Profile 02 | Gas density switch and alarm controller | Diaphragm or piston sensing with calibrated pressure compensation | SF₆, nitrogen, compressed air, insulating gases | Application-specific set points | Switching accuracy typically ±2% of set point | Relay contacts, alarm output, optional 4–20 mA | G 1/4, NPT 1/4, or customized adapter | Ex certification depends on enclosure and order code | CE and ISO 9001 may be offered; request current certificate copies |
| Manufacturer Profile 03 | Inline gas composition and density analyzer | Ultrasonic or speed-of-sound measurement | Natural gas, biogas, hydrogen blends, process gas | 0.3–1.5 kg/m³, dependent on gas mixture | Typically ±0.5–1.5% of reading | 4–20 mA, RS-485, Ethernet options | DN15–DN100 flanged or threaded installation | Optional explosion-protected enclosure | Calibration traceability should be confirmed for each gas mixture |
| Manufacturer Profile 04 | Portable gas density tester | Vibrating-element or oscillating-tube measurement | Laboratory gas mixtures, natural gas, specialty gases | 0.1–2.0 kg/m³ | Typically ±0.1–0.5% of reading | Display, USB, data logging, optional Bluetooth | Quick-connect sampling inlet | Usually for non-hazardous areas unless separately certified | Calibration certificate should state reference gas, temperature, and pressure |
| Manufacturer Profile 05 | Gas density relay for electrical equipment | Pressure-density conversion using sealed reference volume | SF₆-insulated switchgear and medium-voltage equipment | Equipment-specific nominal density range | Alarm and lockout thresholds defined by equipment design | Independent alarm, warning, and lockout contacts | Metric or NPT threaded connection | Indoor and outdoor enclosure options | IEC 62271-related application requirements should be checked with the equipment integrator |
| Manufacturer Profile 06 | Industrial gas density monitor | Thermal mass or thermal conductivity sensor | Furnace atmosphere, inerting systems, gas blending | 0.05–3.00 kg/m³ | Typically ±1.0–2.0% of full scale | 4–20 mA, relay, RS-485/Modbus | Sample-draw cell or direct insertion probe | Optional protection for classified installations | RoHS and CE declarations may apply; verify the applicable product directive |
| Manufacturer Profile 07 | Gas density and specific-gravity analyzer | Pressure, temperature, and composition compensation | Pipeline gas, fuel gas, custody-support applications | 0.5–1.2 kg/m³ for common natural-gas mixtures | Typically ±0.5–1.0% of reading | 4–20 mA, HART, Modbus, pulse or alarm output | Flanged flow cell or bypass sampling system | Ex d or Ex ia options may be available | Confirm compliance with local metrology and pipeline requirements |
| Manufacturer Profile 08 | OEM gas density sensor module | MEMS thermal sensing or micro-machined flow channel | Medical gas equipment, laboratory instruments, gas cabinets | Application-specific; generally low-flow gas service | Typically ±1–3% after system calibration | Analog voltage, UART, I²C, or RS-485 | Manifold, tubing, or PCB-mounted configuration | Generally not intended for hazardous areas without system certification | System-level EMC, RoHS, and safety assessment recommended |
| Manufacturer Profile 09 | High-pressure gas density transmitter | Pressure-density algorithm with digital temperature compensation | Compressed natural gas, hydrogen storage, industrial cylinders | 0.05–2.00 kg/m³; pressure range is model-dependent | Typically ±1.0% of calibrated range | 4–20 mA, RS-485/Modbus, configurable alarms | High-pressure threaded or welded connection | Hazardous-area suitability must be confirmed for the complete assembly | Pressure-equipment and gas-safety documentation should be requested |
| Manufacturer Profile 10 | Custom gas density and process monitoring system | Combined pressure, temperature, thermal, and flow measurements | Chemical processing, hydrogen production, gas mixing, utilities | Configured to the gas composition and process conditions | Project-specific; commonly ±0.5–2.0% | 4–20 mA, HART, Modbus TCP/RTU, Ethernet, relay | Customized sample conditioning or inline skid | Ex d, Ex ia, or non-hazardous configurations by project | Certification package is project-specific and should include calibration and conformity records |