| Routine Quality Control | 0.2–100 N | 100 N, with a resolution of at least 0.01 N | 90° ± 1.0° | 50–300 mm/min | Within ±2% of the set speed | Specimen and grip centerlines aligned within 1.0 mm | Up to 300 mm | Check the angle with a calibrated digital inclinometer and verify speed over a measured travel distance | Adhesive tapes, labels, films, and packaging seals |
| General Laboratory Testing | 0.05–500 N | 500 N, with a resolution of at least 0.05 N | 90° ± 0.5° | 10–500 mm/min | Within ±1% of the set speed | Parallel grip faces; lateral offset no greater than 0.5 mm | Up to 500 mm | Use a calibrated angle block or inclinometer, a displacement check, and a grip-parallelism gauge | Coated substrates, flexible laminates, medical tapes, and protective films |
| Low-Force Adhesive Testing | 0.005–50 N | 50 N, with a resolution of at least 0.005 N | 90° ± 0.5° | 1–300 mm/min | Within ±1% of the set speed | Self-aligning grip or guided fixture to minimize bending and twisting | Up to 300 mm | Perform zero-load stability, angle, speed, and alignment checks before each test series | Low-tack labels, skin-contact adhesives, thin films, and release liners |
| High-Force or Reinforced Materials | 1–2,000 N | 2,000 N, with a resolution of at least 0.2 N | 90° ± 1.0° | 10–250 mm/min | Within ±2% of the set speed | Rigid fixture with reinforced mounting; offset no greater than 1.0 mm | Up to 500 mm | Inspect fixture deflection under load and confirm angle under the expected working force | Reinforced tapes, construction membranes, heavy laminates, and bonded composites |
| Standards-Based Research Testing | Selected according to specimen and adhesive system | Choose a capacity so the expected peak force is between 10% and 90% of full scale | 90° ± 0.5° or tighter when required by the test method | Programmable from 1–500 mm/min | Within ±1% of the set speed across the selected range | Grip alignment verified before testing and maintained throughout the peel stroke | At least 500 mm, subject to specimen dimensions | Document angle, speed, force calibration, fixture condition, specimen width, and conditioning procedure | Method development, comparative studies, and testing aligned with ASTM D3330 or ISO 8510-1 principles |
| Automated Repetitive Testing | 0.05–1,000 N | Selected interchangeable load cells covering the expected force range | 90° ± 0.5° during the complete test stroke | 10–500 mm/min with programmable presets | Within ±1% of the programmed speed | Fixed reference fixture, repeatable specimen positioning, and automatic alignment check | Up to 1,000 mm | Use scheduled calibration, automatic travel verification, and periodic fixture repeatability checks | Production audits, batch comparison, and high-volume adhesive product evaluation |