| Initial sizing and operating-point screen |
| DC bus | 48 V nominal; verify operation across the actual minimum and maximum supply voltage. | 48 V class | 48 V class | 48 V class |
| Target speed | 3,000 rpm at the required continuous operating point. | 3,000 rpm | 3,000 rpm | 3,000 rpm |
| Required continuous torque | 0.80 N·m. Confirm the load profile and include acceleration, friction, and transmission losses. | 1.00 N·m rated; 25% torque margin | 0.75 N·m rated; −6.3% margin | 1.20 N·m rated; 50% torque margin |
| Required peak torque | 1.60 N·m for short-duration acceleration or load peaks; confirm permitted duration and duty cycle. | 2.00 N·m peak; 25% torque margin | 1.50 N·m peak; −6.3% margin | 2.20 N·m peak; 37.5% torque margin |
| Approximate continuous mechanical power | 251 W, calculated as torque × angular speed: 0.80 N·m × 2π × 3,000 / 60. | 314 W at 1.00 N·m and 3,000 rpm | 236 W at 0.75 N·m and 3,000 rpm | 377 W at 1.20 N·m and 3,000 rpm |
| Preliminary sizing result | Check the torque-speed curve at the actual bus voltage and cooling condition; torque ratings alone do not confirm usable power. | Meets example torque screen | Does not meet continuous or peak torque | Meets example torque screen; larger reserve |
| Performance verification and safety margins |
| Continuous-load test | Run at 3,000 rpm and 0.80 N·m until temperatures stabilize. Pass only if speed, current, and temperatures remain within documented limits. | Pending test | Pending test; screening indicates insufficient torque rating | Pending test |
| Peak-load test | Apply 1.60 N·m for the application’s specified peak duration and repetition rate. Verify the motor and controller peak-current limits. | Pending test | Pending test; screening indicates insufficient peak torque | Pending test |
| Speed and torque measurement | Use a calibrated dynamometer or equivalent torque-and-speed instrumentation; record steady-state and transient results. | Record measured rpm and N·m | Record measured rpm and N·m | Record measured rpm and N·m |
| Thermal safety check | Measure winding temperature directly or use a validated temperature estimate. Example project target: winding temperature ≤120°C at 40°C ambient; this is not a universal motor limit. | Pending; compare with motor and insulation limits | Pending; compare with motor and insulation limits | Pending; compare with motor and insulation limits |
| Electrical and controller check | Measure phase or DC current and check controller, connector, and cable ratings at the actual supply extremes. Verify overcurrent and overtemperature protection. | Pending; document maximum current | Pending; document maximum current | Pending; document maximum current |
| Final selection rule | Select only after the required operating points pass dynamometer and thermal tests, the full torque-speed curve is adequate, and motor, controller, and wiring limits retain the project’s specified safety margin. |